Skip to content
Meet our Integrity professionals at the Banff Pipeline Workshop, 12–15 April 2027 See the event →
ACiD Integrity Inc.
Search Request a quote
ACiD Integrity Inc.
Search Quote

ACiD INTEGRITY · CORROSION ENGINEERING

Corrosion engineering, products and data, in one place

We design, install and monitor cathodic protection and AC mitigation across North America and beyond: integrity professionals, our own crews and our own data tools, on many projects at once.

Technician recording readings beside a pipe run
PILOT FRANK pilot: 90 days correlating your live monitoring feed with your ILI and CP history on one segment, so events are ranked by risk. Apply for the pilot →

ACTIVE PROTECTION

Protection that works every hour, not only on survey day

An impressed-current system pushes protective current from an anode bed, through the soil, onto your pipe. Remote readings from the rectifier and test points reach our Integrity professionals, who act on the trend before it becomes a finding.

  1. PowerThe rectifier drives a controlled current into the anode bed.
  2. ProtectCurrent flows through the soil and polarises the pipe surface.
  3. MeasureTest points record pipe-to-soil potential, around the clock.
  4. ActAn Integrity professional reviews the trend and adjusts output before protection drops.
How we design and monitor CP
Diagram: how an impressed-current cathodic protection system protects a pipeline and is monitored ILLUSTRATIVE0 m−1.5 m−2.0 mTS-02 · KP 1+200−1,080 mVRECTIFIER R-112.4 V · 6.2 AAnodes · in backfillCurrent paths · modelledProtected pipeIllustration · not to scale

TECHNOLOGY & DATA

From field readings to decisions you can defend

Every survey, test point and remote reading lands in our own data environment. We cross-reference it with multiple accessible data sets and historical trends, run it through Python models, specialist modelling software and machine-learning tools we build ourselves, and our project management and engineering teams oversee the whole process and keep you in the loop.

Diagram: field data flows through ACiD’s data environment and models to an Integrity professional and a decision Field dataSurveys, test points, collected dataEnriched dataMultiple data sets and historical trendsModelsPython, ML, specialist softwareIntegrity professional reviewAn Integrity professional checks the resultDecisionDesign, report, portalIllustration · not to scale
  • Our own data environmentReadings are stored once, traceable from the field to the report.
  • Models we buildMachine-learning and Python models trained on our own factual, evidence-based enriched data, alongside industry-leading software.
  • AI where it helpsAI-enabled tools across our data work, always with an Integrity professional accountable for the answer.
AMPP CP Level 4Specialist-certified integrity professionals
ISNetworldContractor prequalified
AvettaSupplier prequalified
ComplyWorksCompliance verified

WHAT WE DO TODAY

Engineered by Integrity professionals. Installed by our own crews.

Every system starts with an Integrity professional and finishes with our own crew in the field: one team from the first calculation to the commissioning survey.

Engineering

  • CP system design and sizing
  • AC mitigation and interference studies
  • Integrity and remaining-life assessment
  • Design review and sign-off by an Integrity professional
See Integrity Engineering →

Field installation

  • Deep and shallow anode beds
  • Rectifier installation and relocation
  • Test stations, bonds and thermite connections
  • Commissioning surveys against criterion
See installation and commissioning →
Illustration: a crew member takes a reading at a test post above a protected pipeline
7
Level 4
AMPP CP Specialist-certified integrity professionals
7
Specialist disciplines, from cathodic protection to Intelligence Engineering
14
Use case examples, from pipelines to tanks and beyond
4
Technical societies our people take part in

WHAT WE DO

Specialist disciplines, one team from design to turnover

01
Integrity Engineering
Engineering first. We design cathodic protection systems and assess the integrity of buried and submerged assets, with an Integrity professional accountable for every design, calculation and recommendation.
Explore →
02
Cathodic Protection
Design, surveys, compliance and supply for steel and concrete in soil and water.
Explore →
03
AC Interference / Mitigation
Induced-AC testing, modelling and grounding where pipe shares a corridor with power.
Explore →
04
DC Interference
Find the source, prove it, fix it. Common sources are DC transit systems and foreign-owned CP systems.
Explore →
05
Installation and Commissioning
Our own PMs, supervisors and crews, anywhere in North America and beyond. Turned over in a day.
Explore →
06
Pipeline Integrity and ECDA
Over-the-line surveys and risk ranking that tell you where to dig, and where not to.
Explore →
07
Intelligence Engineering
Python, machine learning and AI layers that set your historical data against current readings and continuous monitoring feeds, and turn what they show into decisions and actions.
Explore →

INDUSTRIES

Where our programs protect assets

CASE STUDY 01 · BRITISH COLUMBIA

One project, one thread

A 200 ft MMO anode bed installed and commissioned in two field days. Every update, approval, reading and invoice ran through one project record.

200 ft
Linear MMO anode
2 days
Field install
6 of 6
Test points past −850 mV
0
Open deficiencies

PRODUCTS

The tools behind our field work, open to clients

BEHIND EVERY PROJECT

Tools that give our people more time with you

We invest in tools so the routine runs itself, and our project managers and Integrity professionals spend their time talking with you.

Specialized field equipment
Survey, testing and installation kit our crews own and maintain.
Specialized engineering software
CP design, AC modelling and integrity calculations.
Specialized modelling software
Python and machine-learning models built on our own enriched data.
High-capacity computing
The computing power to run large data sets and models quickly.
Displays and dashboards
Clear views of your assets, readings and next actions.
Customer engagement
One project record, regular updates and a person you can reach.
Data sets lined up on one pipeline: inline inspection, surveys, coating, soil and temperature, and test-point readings, correlated into one risk ranking for an Integrity professional to review.

INNOVATION

Certified Integrity professionals, our own crews, better tools

AMPP CP Level 4 Specialist-certified integrity professionals and our own crews, backed by ACiD Pi OS, our project intelligence system. We build new models and new ways of understanding data, and prove them on our own test sites before they become how we work. We are also beginning research work with universities and colleges.

Research, development and innovation →
Have an asset that needs protecting?
Request a quote
AMPP CP Level 4ISNetworldAvettaComplyWorks