CASE STUDY 11 · THE PRAIRIES · SOLUTION MINING
Turnkey cathodic protection for 24 hot well casings on a solution-mining pad
Design, supply, installation and commissioning by one team: twelve deep anode beds and six rectifiers protecting 24 well casings that run about 1,800 m down, carrying brine hotter than 80 °C.
Solution-mining operator · well pad of injection and production wells
- Cathodic Protection
- Deep anode beds
- Installation and Commissioning
The problem
A new well pad had 24 injection and production well casings, each about 1,800 m long and spaced about 7 m apart, carrying brine at more than 80 °C. Hot bare steel needs far more protective current than a typical buried pipe, and the casings are tied into the pad's piping. The operator asked ACiD to deliver the external cathodic protection turnkey: design, supply, install and commission.
What we did
- 01Measure the ground firstFour-pin soil resistivity testing gave about 2,500 Ω·cm down to 20 m and about 3,000 Ω·cm from 20 m to 100 m. That is higher than on earlier pads, so the system was sized for it.
- 02Design for hot steelAbove 60 °C the criterion is a polarized potential of −950 mV CSE or more negative. A total requirement of about 570 A came from theory and field data from earlier pads, with current density modelled along the casings.
- 03Twelve deep anode bedsEach bed is a 203 mm hole about 90 m deep with a flexible MMO linear anode in pumped coke breeze, at least 25 m apart and 45 m from the nearest casing. Six 60 V rectifiers, one per four casings, synchronised for true off readings.
Have a similar asset?
Tell us about the wells, pad or line. An Integrity professional reads every request, and anything that needs a stamp goes to one of our Professional Engineers.