Skip to content
Meet our Integrity professionals at the Banff Pipeline Workshop, 12–15 April 2027 See the event →
ACiD Integrity Inc.
Search Request a quote
ACiD Integrity Inc.
Search Quote
HomeCase studiesTurnkey cathodic protection for 24 hot well casings on a solution-mining pad

CASE STUDY 11 · THE PRAIRIES · SOLUTION MINING

Turnkey cathodic protection for 24 hot well casings on a solution-mining pad

Design, supply, installation and commissioning by one team: twelve deep anode beds and six rectifiers protecting 24 well casings that run about 1,800 m down, carrying brine hotter than 80 °C.

Solution-mining operator · well pad of injection and production wells

  • Cathodic Protection
  • Deep anode beds
  • Installation and Commissioning
24
Well casings protected, about 1,800 m each
12
Deep anode beds, about 90 m deep
6
Rectifiers, each delivering 81 to 87 A at commissioning

The problem

A new well pad had 24 injection and production well casings, each about 1,800 m long and spaced about 7 m apart, carrying brine at more than 80 °C. Hot bare steel needs far more protective current than a typical buried pipe, and the casings are tied into the pad's piping. The operator asked ACiD to deliver the external cathodic protection turnkey: design, supply, install and commission.

Section through a solution-mining well pad: 24 well casings about 1,800 m deep, protected by twelve deep anode beds about 90 m deep set at least 45 m away, and six rectifiers at 81 to 87 A each.

What we did

  1. 01
    Measure the ground first
    Four-pin soil resistivity testing gave about 2,500 Ω·cm down to 20 m and about 3,000 Ω·cm from 20 m to 100 m. That is higher than on earlier pads, so the system was sized for it.
  2. 02
    Design for hot steel
    Above 60 °C the criterion is a polarized potential of −950 mV CSE or more negative. A total requirement of about 570 A came from theory and field data from earlier pads, with current density modelled along the casings.
  3. 03
    Twelve deep anode beds
    Each bed is a 203 mm hole about 90 m deep with a flexible MMO linear anode in pumped coke breeze, at least 25 m apart and 45 m from the nearest casing. Six 60 V rectifiers, one per four casings, synchronised for true off readings.

Have a similar asset?

Tell us about the wells, pad or line. An Integrity professional reads every request, and anything that needs a stamp goes to one of our Professional Engineers.

Have an asset that needs protecting?
Request a quote